Technical parameters of the X-ray machine


High-voltage generator 1.1, Maximum output power of high-voltage generator: 50KW 1.2, Maximum tube voltage: 150KV 1.3, High-voltage generator inversion frequency

High-voltage generator
1.1. Maximum output power of the high-voltage generator: 50KW
1.2. Maximum tube voltage: 150KV
1.3. High-voltage generator inversion frequency: 50KHz
1.4. Maximum tube current: ≥600mA
1.5. Maximum mAs: 600-800mAs
X-ray tube support
2.1. Vertical X-ray tube support
2.2. Vertical movement range: 1200-1900mm
2.3. Longitudinal movement range: 1700-2500mm
2.4. Transverse movement range: ≥220mm
Radiography table
3.1. Tabletop horizontal longitudinal movement range: 850-1000mm
3.2. Tabletop horizontal transverse movement range: 220-250mm
3.3. Can be automatically electrically fixed
3.4. With movable or fixed grid, grid ratio: ≥10:1, grid density: ≥40 lines/cm
Chest radiography stand
4.1. With movable or fixed grid, grid ratio: ≥10:1, grid density: 40-78 lines/cm
5. Radiation safety protection: Complies with international radiation safety protection standards

Mobile, range, generator, high voltage, fixed, protection, radiation

Other News


2024 Social Responsibility Report

Establishing standardized corporate management systems is the intrinsic driving force behind a company's sustainable development.


The company successfully passed the 2015 audit by the China Quality Certification Center

On September 27, 2015, the China Certification and Accreditation Administration (CNCA) conducted the 2015 annual surveillance and audit


The discovery of X-rays

In 1895, while studying the phenomenon of gas discharge in a cathode ray tube, German physicist Wilhelm Conrad Röntgen discovered that a screen coated with barium platinocyanide


The nature of X-rays

Penetration ability refers to the ability of X-rays to pass through matter without being absorbed. X-rays can penetrate substances that are opaque to visible light.


The application of X-rays in medicine

X-rays are used in medical diagnosis, primarily based on their penetrating power, differential absorption, photosensitivity, and fluorescence.


The function of a large X-ray machine

High-frequency inverter technology achieves high-definition imaging with low-dose exposure. High-power, high-kV, high-mA load output meets the needs of whole-body photography.